Laboratory micromotor. Grinding, cutting and polishing of prosthetic restorations

Advantages

  • Ergonomic handpiece significantly lowers vibration
  • Excellent perfomance in all its uses
  • Greater dependability and simple maintenance procedures
  • 1-year warranty

Characteristics

  • DC traditional-type motor (with manifold) with high torque value with maximum speed 27.000 rev/min
  • Ares 45: Brushless DC motor (without manifold) with very high torque value with maximum rotation speed 45.000 rev/min. Constant torque with speed variation
  • Electronic control with microprocessor to optimise motor performance and endurance
  • Precision mechancs with high quality materials and components
  • Software developed in "Fuzzy Logic"
  • Pedal controls speed variations
  • Command for rotation direction inversion

 

Discontinued product, available while supplies last.

Technical Data

Ares 27
Handpiece size
Ø28 /L211
Control panel size
L19 cm / P19 cm /H10 cm
Control weight
3.5 Kg
Handpiece power
122 Watt
Total power
180  Watt
Voltage (V - Hz) 230 V ± 10% / 50-60  Hz
Handpiece weight 0.37 Kg
Engine torque 4.3 NM

Ares 45
Handpiece size
Ø28 /L211
Control panel size
L19 cm/ P19 cm/H10 cm
Control weight
3.5 Kg
Handpiece power
230 Watt
Total power
300 Watt
Voltage  (V - Hz) 230 V ± 10% / 50-60  Hz
Handpiece weight 0.37 Kg
Engine torque 6.5 NM

Packaging

C306105 Ares 27 Micromotor
C306104 Ares 45 Micromotor

Accessories

XI0110140 Pincer key

Weight and overall dimensions

DIMENSIONS MAIN UNIT
WITHOUT PACKING
WITH PACKING*
Height mm. 100 mm. 250
Length mm. 195 mm. 400
Length with support
mm. 250  
Depth mm. 190 mm. 550
Weight Kg 2.5 Kg 9.5
* The pack includes the handpiece and the pedal control unit
DIMENSIONS HANDPIECE WITHOUT PACKING
Length mm. 175
Diameter (max) mm. 28
Weight Kg. 0.37

DIMENSIONS PEDAL CONTROL UNIT
WITHOUT PACKING
Height mm. 60
Length mm. 108
Depth mm. 180
Weight Kg. 3.5

Troubleshooting

ISSUE
CAUSE
REMEDY
During work, the micromotor stops
suddenly: “°C” or “HI” appears
on the display.
1. The protection fuse has blown.
2. The power supply unit safety
device has tripped
(see par. 7.2 of maintenance and use manual).
1. Replace the fuse with one of
identical specifications (T1 AH
250V). Contact an
Authorised Service Centre.
2. Proceed as described in par. 7.2.
Should the problem persist contact
an Authorised Service Centre.
To read all the documents in PDF format, you need to download a PDF viewer program. We suggest Adobe® Acrobat® Reader program, available for free from the following web site: www.adobe.com Note: programs versions are available for all operating systems.

© Zhermack SpA - All rights reserved - Via Bovazecchino, 100 45021 Badia Polesine (RO), Italy
Tel. +39 0425 597611 - Fax. +39 0425 53596 - Email web@zhermack.com
P.IVA 00594630295 - C.F. P.IVA IT00594630295 - R.E.A. 86603 - R.I. RO 00594630295 - M. RO 001381Isc. Reg. A.E.E. IT07111000002 - Cap. Soc. € 1.032.000,00

Credits - Terms and Conditions of Use - Work with us